Vascular Access Trainers
Arterial Puncture Wrist
Manufacturer: Limbs & Things
Palpable arterial pulse, variable speed of pulse, needle insertion, observable 'Flash Back,' blood collection
Features
- Radial arterial puncture
Arterial Stick Arm
Manufacturer: Laerdal
Lifelike adult male arm reproduction with infusible arteries designed for training the proper arterial puncture procedure for blood gas analysis.
Features
- Simulation of hand placement during performance of Allen's Test is possible
- Flexible wrist enables proper positioning
- Arterial pressure may be generated manually
- Artery palpation is possible
- Percutaneous puncture sites in both brachial and radial artery
- Infusible arteries with ability to pressurize system, enable blood backflow in syringe
- Articulates to adult male manikins
CentralLineMan
Manufacturer: Simulab
CentraLineMan is the most widely used Central Venous Catheterization training solution in the market today. This flexible system offer unsurpassed value with clinically relevant anatomy, time-tested ultrasound compatible tissues that maintain visual acuity, market leading durability from needle sticks to full catheterizations all with the ability to interchange the Articulating Head, Body Form Base and Tissues with many of Simulab’s other procedural task trainers.
Features
- Practice full central venous catheterization using ultrasound guided or blind/landmark insertion approaches at the subclavian, supraclavicular, and internal jugular access sites
- Practice placing patient in appropriate position per access site standards
- Gain experience in identifying and selecting appropriate access site based on patient anatomical variations
- Practice use of ultrasound for:
- Developing psychomotor skills required for obtaining visualization during cannulation
- Detecting anatomical variations
- Distinguishing vessels
- Visualizing arterial pulse and venous
compression - Identifying anatomical location of target
vessel - Visualizing needle cannulation of target
vessel in transverse view - Visualize threading of guidewire in
longitudinal axis view - Visualizing catheter placement
- Reducing rate of mechanical complications
due to anatomical variance
such as pneumothorax or arterial puncture - Improving first cannulation success and
decreasing needle passes - Practice palpating external landmarks to
identify vessel location - Practice identifying unsuccessful vessel
access by fluid feedback representing
arterial puncture
Central Line Training Model
Manufacturer: Blue Phantom
Blue Phantom is proud to introduce the most realistic ultrasound central line mannequin available anywhere. Constructed utilizing our innovative LifeCast™ modeling approach, the external landmarks were cast from a live human while the internal anatomy is based on digital human files. This ultra-durable ultrasound simulator incorporates all of the anatomy required to teach, learn and practice the skills associated with central line placement and was designed for both ultrasound guided and blind insertion procedural training. Our self-healing tissue withstands tremendous use, minimizing the need for replacement parts. Blue Phantom’s new upper torso central venous catheter model offers clinicians the most life-like training environment at a low cost of ownership. Perform complete central line placements of the internal jugular and subclavian vein - including needles, guidewires, dilation and threading of catheters.
Features
Female Multi-Venous IV Training Arm Kit
Manufacturer: Laerdal
Lifelike adult female arm reproduction with multi-vein system designed for peripheral intravenous therapy.
Features
- Venipuncture possible in the antecubital fossa or dorsum of the hand
- Peripheral IV line insertion and removal
- Accessible veins include median, basilic and cephalic
- Palpable veins enable site selection and preparation
- Infusible veins allow peripheral therapy with IV bolus or push injection method
- Peripheral IV line maintenance including assessment and rotation of site and dressing, solution and tubing change
- Replaceable skin and multi-vein system ensures longevity of model
FemoralLineMan
Manufacturer: Simulab
FemoraLineMan is an ultrasound compatible task trainer that offers an effective training solution for central venous or arterial access using the femoral vein route. This femoral line trainer uses the same patented technology as the highly acclaimed TraumaMan System and allows medical professionals to train using real-time ultrasound guidance during catheter placement.
Features
- Anatomically correct, ultrasound compatible, body form, with all relevant palpating landmarks and vascular anatomy
- Self-sealing tissues and veins provide the greatest value, in frequency of needle sticks and full catheterizations per access site, of any trainer on the market
- Exceptional ultrasound imaging through repeated use—needle sticks and full catheterizations do not degrade the image acuity
- Two colors of simulated blood differentiate the arterial and venous vessels—provides immediate feedback of unsuccessful cannulation
- Arterial pulse is present and vein realistically compresses under palpation
- Easily adjustable venous pressure regulator allows for vein compression or low pressure simulation scenarios
- Replaceable tissues come pre-filled with blue venous and red arterial fluid
- Tissues can remain filled when not in use, and are easy to refill with provided fluid when necessary
IS Nerve Block Trainer with Smartissue & Articulating Head
Manufacturer: Simulab
Brachial Plexus Nerve Block Training Interscalene / Supraclavicular Block for the Nerve Block Training System is ultrasound compatible and allows for both the interscalene and supraclavicular blocks. It simulates nerve stimulation using Simulab’s patent pending SmarTissue™, which allows the tissue to communicate with a PC, showing the user when the needle or catheter are proximal to or in contact with the C5, C6, or C7 nerve.
Features
- Includes body form with a replaceable SmarTissue, nerve stimulator electronics, and SmarTissue software (PC compatible*)
- Ultrasound compatible for guidance during needle sticks and catheter placement
- Anatomically correct human torso with landmarks for enhanced realism
- Distinct “pop” is visualized and palpated when the needle enters into the neural sheath
- SmarTissue software interprets unique signals, illuminating a green circle if the needle is proximal to the nerve and a red dot if the needle is inserted into the nerve
- Articulating head increases realism
Landmarks
- Sternocleidomastoid muscle
- Clavicle head
- Interscalene groove
- Internal jugular and carotid artery (which pulses)
- Anterior and middle scalene muscle
- Brachial plexus
IV and Arterial Line Vascular Access Ultrasound Trainer
Manufacturer: Blue Phantom
Using US system controls, transducer positioning/movement, arm w/ pulse pump and cephalic vein, radial artery, ulnar artery and superficial veins of the lower arm
Features
- US arterial, venous access
Leg Femoral and Saphenous Vein Venous Access Ultrasound Trainer
Manufacturer: Blue Phantom
Blue Phantom’s leg vascular access ultrasound training mannequin model allows users to develop and practice the skills necessary to gain proficiency in using ultrasound to guide needle and catheter insertions in the saphenous and femoral vein. Using Blue Phantom proprietary simulated human tissue, this very realistic and ultra-durable venous access ultrasound training mannequin is excellent for training clinicians in the psychomotor skills associated with ultrasound guided vascular access procedures. These ultrasound imaging skills include; using ultrasound system controls, transducer positioning and movement, recognition of venous anatomy, using ultrasound to target the appropriate vessels for cannulation, and performing a central venous access procedure. Additionally, a deep vein thrombosis (DVT) option allows users to learn to identify the presence of thrombus in the deep vessels.
Features
- Saphenous, femoral and accessory vessels are present in this venous access ultrasound training model mannequin
- Ultra-durable self healing tissue is extremely realistic in ultrasound imaging characteristics and feels like real human tissue
- Contains anatomically correct vascular anatomy of the right upper and mid leg including the saphenous, femoral and tributary veins
- Performs well using any ultrasound imaging system
- Contains anatomically correct vascular anatomy of the right upper and mid leg including the saphenous, femoral and tributary veins
Male Multi-Venous IV Training Arm Kit
Manufacturer: Laerdal
Lifelike adult male arm reproduction with multi-vein system designed for peripheral intravenous therapy.
Features
- Venipuncture possible in the antecubital fossa or dorsum of the hand
- Peripheral IV line insertion and removal
- Accessible veins include median, basilic and cephalic
- Palpable veins enable site selection and preparation
- Infusible veins allow peripheral therapy with IV bolus or push injection method
- Peripheral IV line maintenance including assessment and rotation of site and dressing, solution and tubing change
- Replaceable skin and multi-vein system ensures longevity of model
Pediatric Intraosseous Trainer
Manufacturer: Laerdal
Intraosseous needle insertion, aspiration of simulated bone marrow, replaceable pads are pre-filled with simulated bone marrow
Features
- Intraosseous needle insertion
Vascular Access Child
Manufacturer: Simulab
Vascular catheterization, use of US during procedure, palpation of landmarks and access through internal jugular, subclavian, and femoral
Features
- Central and femoral line using US guidance